Search results for "Limit values"

showing 6 items of 6 documents

Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and t…

2012

A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWS…

Environmental EngineeringairLegionellawaterAir MicrobiologyDentistryTotal Viable CountsurfacesDental Equipmentdental unit water systemToxicologyTap waterEnvironmental monitoringEnvironmental ChemistryMedicineHumansThreshold Limit ValuesWaste Management and DisposalAir Microbiology Dental Clinics Dental Equipment; microbiology Environmental Monitoring; standards Equipment Contamination Humans Italy Threshold Limit Values Water Microbiologybiologybusiness.industryDental ClinicsDental EquipmentmicrobiologyDental Equipment; Environmental Monitoring; Humans; Italy; Threshold Limit Values; Air Microbiology; Dental Clinics; Equipment Contamination; Water MicrobiologyLiterContaminationdental clinic; microbiological contanimation; dental unit water system; air; surfaces; watermicrobiological contanimationbiology.organism_classificationPollutionItalyEquipment ContaminationstandardsEquipment Contaminationdental clinicbusinessWater MicrobiologyEnvironmental Monitoring
researchProduct

External and internal exposure to polycyclic aromatic hydrocarbons (PAH) among workers in the production of fire-proof materials – Proposal of a biol…

2006

In 1999, we introduced the German polycyclic aromatic hydrocarbons (PAH) study. The study was designed as a nation-wide investigation on workers exposed to PAH. One aim of the study was to establish biological monitoring guidance values (BMGVs) for different branches. Here, we report on the production of fire-proof materials. This branch of industry is typically confronted with high exposure to PAH and with PAH-induced occupational (cancer) diseases. One hundred and thirty-five employees participated in the course of seven sampling dates in four different plants in Germany. External exposure was determined by personal air monitoring of the 16 EPA-PAH. Human biological monitoring was accompl…

AdultPercentilePopulationAir Pollutants OccupationalUrinechemistry.chemical_compoundAir monitoringGermanyOccupational ExposureHumansIndustryPolycyclic Aromatic HydrocarbonsThreshold Limit ValueseducationCreatinineeducation.field_of_studyPyrenesSmokingPublic Health Environmental and Occupational HealthMiddle AgedPhenanthrenesPah exposureSpot urinechemistryEnvironmental chemistryPyreneEnvironmental MonitoringInternational Journal of Hygiene and Environmental Health
researchProduct

Acute effects on the human EEG after an external exposure to 200 ppm methanol

2001

Objectives: Even low concentrations of organic solvents may cause acute effects on the human central nervous system. The German MAK (threshold limit value) of methanol is 200 ppm. The aim of this study was to investigate whether acute exposure to 200 ppm methanol causes adverse effects, measured by EEG, and moreover, whether it is possible to differentiate between sedative and excitatory effects with this method. Methods: Twelve healthy subjects were exposed for 4 h to 200 ppm and to 20 ppm (control) in an exposure chamber in a cross-over design. The EEG was recorded before (reference) and at the end of each exposure with, the subject's eyes closed and opened and during a choice reaction te…

AdultCentral Nervous SystemMaleAcute effectsmedicine.drug_classThreshold limit valueElectroencephalographychemistry.chemical_compoundReference ValuesHumansMedicineSingle-Blind MethodThreshold Limit ValuesInhalation ExposureCross-Over Studiesmedicine.diagnostic_testInhalationbusiness.industryMethanolPublic Health Environmental and Occupational HealthElectroencephalographychemistrySedativeAnesthesiaToxicityExposure chamberMethanolbusinessInternational Archives of Occupational and Environmental Health
researchProduct

Experimental and Modeling Analyses of Human Motion Across the Static Magnetic Field of an MRI Scanner

2021

It is established that human movements in the vicinity of a permanent static magnetic field, such as those in magnetic resonance imaging (MRI) scanners induce electric fields in the human body; this raises potential severe risks of health to radiographers and cleaners exposed routinely to these fields in MRI rooms. The relevant directives and parameters, however, are based on theoretical models, and accurate studies on the simulation of the effects based on human movement data obtained in real conditions are still lacking. Two radiographers and one cleaner, familiar with MRI room activities and these directives, were gait analyzed during the execution of routine job motor tasks at different…

ScannerHistologyComputer scienceBiomedical EngineeringBioengineeringWorkspaceMotion (physics)030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineGait (human)Position (vector)medicineComputer visionstatic magnetic fieldsOriginal Researchmedicine.diagnostic_testbusiness.industryBioengineering and BiotechnologyCentroidMagnetic resonance imagingMagnetostaticsMRI personnel safetyexposure limit valuesArtificial intelligencebusinessDirective 2013/35/EU030217 neurology & neurosurgeryhuman movement analysisTP248.13-248.65BiotechnologyFrontiers in Bioengineering and Biotechnology
researchProduct

Effects on Heat Stress of a Flame-Retardant Ensemble for Aluminum Smelters

2000

A common belief is that a flame-retardant clothing ensemble will increase the level of heat stress over ordinary cotton work clothes. This is supported by bench tests on fabrics that indicate higher insulation and vapor resistance values for flame-retardant clothing. This research compared a flame-retardant clothing ensemble for an aluminum smelter (Zirpo wool shirt and FR8 denim pants) with typical cotton work clothing. Four young men walked on a treadmill at two work levels inside a climatic chamber under controlled conditions of heat stress. During each test, heart rate, core temperature, and skin temperatures were continuously monitored and recorded every 5 min. After a physiological st…

AdultMaleWork (thermodynamics)Threshold limit valuebusiness.industryWet-bulb globe temperatureEnvironmental engineeringPublic Health Environmental and Occupational HealthHumidityHeat Stress DisordersAtmospheric sciencesClothingStress (mechanics)Protective ClothingInflection pointOccupational ExposureMetallurgyHumansEnvironmental scienceRelative humidityThreshold Limit ValuesbusinessAluminumFlame RetardantsAIHAJ
researchProduct

Valeurs de référence du valproate de sodium (CAS n°1069-66-5). Valeurs toxicologiques de référence par voie orale et inhalation, valeurs limites d’ex…

2021

Le site de Sanofi situé à Mourenx, dans le bassin industriel de Lacq (64), produit un médicament antiépileptique, la Dépakine®, dont le principe actif est le valproate de sodium (VPS). Ce site est une installation classée pour la protection de l’environnement (ICPE) soumise à autorisation au titre de l’article L.511-1 et suivants du Code de l’environnement. Les rejets dans l’environnement d’une telle installation sont encadrés par des limites établies sur la base d’une évaluation quantitative des risques sanitaires (EQRS). En 2017, Sanofi Chimie a réalisé une évaluation de l’impact sur la santé et l’environnement des rejets atmosphériques de valproate, en utilisant des valeurs toxicologique…

Valeur toxicologique de référenceIndicateur biologique d’expositionExpertiseTRVMetrologyLieux de travailVTRBiomarkers of exposureValeurs limites biologiquesVLEPSodium valproateMeasurement methodsValeur de référenceAir des lieux de travailValproic acidValproate de sodiumWorkplacesValproateMéthodes de mesurebiological limit valuesWorkplace airOELToxicological reference valueOccupationalMétrologieMilieu professionnel[SDV.TOX] Life Sciences [q-bio]/ToxicologyOccupational exposure limitBiological indicators of exposureExpert assessmentLimit valuesValeurs limitesReference valueAcide valproïque
researchProduct